Thank you for your interest in our available 4MC1-203-5 part on Unlimited NSN. Circuit Breaker is a part that is manufactured by Sensata Technologies Maryland Inc, and it is listed with the part number 4MC1-203-5. This item, along with all of our inventory, is readily available for purchase today with competitive pricing. Our team members are on standby 24/7x365, and they can provide you with rapid lead-times on everything that you need to successfully carry out your operations.
Unlimited NSN is a state-of-the-art purchasing platform for NSN components like 4MC1-203-5 and other obsolete parts, and we carry top requested NSN parts such as 5925004815489. To ensure that our customers only receive items with the utmost quality, we choose to stock our inventory from top global manufacturers such as Sensata Technologies Maryland Inc.
To find the components that you need, explore our available NSN part catalog under FSC 5925 Circuit Breakers, or utilize our user-friendly search engine and find specific items in a matter of seconds. If you are interested in 4MC1-203-5 part number and are ready to begin the purchasing process, we invite you to fill out and submit an Instant RFQ today. Once received, a member of our staff will review and reach out to you in 15 minutes or less to provide a personalized quote based on your provided information. Experience the revolution of parts purchasing today with Unlimited NSN!
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND |
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MAXIMUM AT 400 PCT SINGLE LOCATION |
CSSX | Switch Current Rating And Type In Amps | 2.5 AC AND |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
AFJN | Fragility Factor | MODERATELY RUGGED |
AKPX | Pole Quantity | 1 |
AJEC | Boss Height | 0.150 INCHES MAXIMUM |
CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC SINGLE LOCATION |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
ADAT | Body Width | 0.740 INCHES MINIMUM AND |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 SINGLE LOCATION |
THSD | Thread Series Designator | UNC |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
CPRQ | Reset Method | MANUAL |
CSSX | Switch Current Rating And Type In Amps | 1.0 DC |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
MRC | Decoded Requirement | Clear Text Reply |
ADTV | Case Material | PLASTIC |
CSWP | Switch Voltage Rating And Type In Volts | 250.0 AC AND |
CSWP | Switch Voltage Rating And Type In Volts | 50.0 DC |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
AJWX | Mounting Surface To Terminal End Distance | 2.461 INCHES MINIMUM AND |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.481 INCHES MAXIMUM |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
ADAQ | Body Length | 2.510 INCHES MAXIMUM |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.948 INCHES MAXIMUM |
ADAT | Body Width | 0.760 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.800 MINIMUM AT 300 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 9.000 MAXIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.500 MAXIMUM AT 300 PCT AND |
CMLP | Thread Quantity Per Inch | 32 |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.400 MINIMUM AT 400 PCT AND |
CPRP | Ultimate Trip Time Per Pole In Seconds | 7.000 MINIMUM ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 2 THREADED STUD |
CPRX | Actuator Position Designation | AT POLE ONE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.072 INCHES MAXIMUM |
CQXF | Inclosure Protection Type For Which Designed | EXPLOSION RESISTANT AND |
4MC1-104-10 | 4MC10 450 X4 5 0 0 | 4MC1-104-21 | 4MC1-104-22 |
4MC1-6-10 | 4MC2-1-7 | 4MC17-6-25 | 4MC1-6-10 |
4MC1-104-22 | 4MC1-7-50 | 4MC2-1-7 | 4MC1-104-5 |
4MC1-104-22 | 4MC1-7-50 | 4MC10-220-6-P-P | 4MC13-6-2-5 |
Before You Go, Please Take a Look at NSN Parts Catalog!
Request for Quote